K-factor table and calculator
With an inside radius equal to the thickness, the K-factor is 0.325 (DIN 6935); it rises to 0.400 at R = 2 × T, 0.444 at R = 3 × T and 0.5 from R = 5 × T.
K-factor by inside radius / thickness (DIN 6935)
| R / T | K | Example at T = 2 mm | Bend allowance 90° |
|---|---|---|---|
| 0.5 | 0.250 | R 1 mm | 2.36 mm |
| 0.65 | 0.278 | R 1.3 mm | 2.92 mm |
| 0.8 | 0.301 | R 1.6 mm | 3.46 mm |
| 1 | 0.325 | R 2 mm | 4.16 mm |
| 1.25 | 0.349 | R 2.5 mm | 5.02 mm |
| 1.5 | 0.369 | R 3 mm | 5.87 mm |
| 2 | 0.400 | R 4 mm | 7.54 mm |
| 2.5 | 0.424 | R 5 mm | 9.19 mm |
| 3 | 0.444 | R 6 mm | 10.82 mm |
| 4 | 0.476 | R 8 mm | 14.06 mm |
| 5 | 0.500 | R 10 mm | 17.28 mm |
| 8 | 0.500 | R 16 mm | 26.70 mm |
K = (0.65 + 0.5 × log10(R / T)) ÷ 2, at most 0.5. Bend allowance for a 90° bend in 2 mm sheet.
The air-bend radius each thickness gets
| Thickness | Usual V-die | Inside radius | R / T | K |
|---|---|---|---|---|
| 0.8 mm | V 6.4 | ≈ 1.1 mm | 1.33 | 0.36 |
| 1 mm | V 8 | ≈ 1.3 mm | 1.33 | 0.36 |
| 1.5 mm | V 12 | ≈ 2.0 mm | 1.33 | 0.36 |
| 2 mm | V 16 | ≈ 2.7 mm | 1.33 | 0.36 |
| 2.5 mm | V 20 | ≈ 3.3 mm | 1.33 | 0.36 |
| 3 mm | V 24 | ≈ 4.0 mm | 1.33 | 0.36 |
| 4 mm | V 32 | ≈ 5.3 mm | 1.33 | 0.36 |
| 5 mm | V 40 | ≈ 6.7 mm | 1.33 | 0.36 |
| 6 mm | V 48 | ≈ 8.0 mm | 1.33 | 0.36 |
| 8 mm | V 64 | ≈ 10.7 mm | 1.33 | 0.36 |
Air bending on the usual die (8 × T up to 8 mm, 10 × T up to 10 mm, 12 × T above): the sheet takes an inside radius of about V ÷ 6, whatever the punch.
The sharpest inside radius by material
| Material | Sharpest inside radius | Tensile strength used | K at that radius |
|---|---|---|---|
| Mild steel S235 / S355 | 0.7 × T | 450 MPa | 0.29 |
| Stainless steel | 1.0 × T | 700 MPa | 0.33 |
| Aluminium | 1.0 × T | 250 MPa | 0.33 |
| Copper and brass | 0.5 × T | 300 MPa | 0.25 |
What CadQuoter's press brake check uses: a part with a tighter radius goes to the shop for review. Tensile strengths are typical values for the force calculation.
How it's calculated
The K-factor gives the position of the neutral layer, the layer of a bend that keeps its length, as a share of the thickness measured from the inside. It is what turns a bent part into the right flat blank: the bend allowance is angle × (R + K × T).
In a gentle bend (large radius) the neutral layer stays in the middle of the sheet: K = 0.5. The tighter the bend, the more the inside is squeezed and the further the layer moves towards it. DIN 6935 puts this into one formula using the correction factor k = 0.65 + 0.5 × log10(R / T), which places the layer at k × T ÷ 2 from the inside. As a K-factor that is:
K = (0.65 + 0.5 × log10(R / T)) ÷ 2, at most 0.5 (from R / T = 5 on)
So K = 0.250 at R = 0.5 × T, 0.325 at R = T, 0.400 at R = 2 × T, 0.444 at R = 3 × T.
Two practical points decide which radius you put in:
- In air bending the die sets the radius, not the punch. The sheet takes an inside radius of about V ÷ 6. 2 mm sheet on its usual V16 gets about 2.7 mm, an R / T of 1.33 and so a K of 0.36; 6 mm on a V60 gets about 8.0 mm and K = 0.36. Use the radius your press brake makes, not the one on the drawing, unless you bottom or coin the bend.
- Material matters less than the radius. DIN 6935 doesn't depend on the material; harder material (stainless, high-strength steel) springs back more and is bent on a wider die, which changes the radius and so K. That's why a test bend on your own machine beats any table.
To work K back from a test bend: cut a strip of known length, bend it once and measure both legs on the outside. The bend took the strip's length minus the straight parts of the legs (each leg minus the outside setback), which is its bend allowance; K follows from bend allowance ÷ angle − R, divided by T. Measure carefully: with 2 mm sheet a 0.1 mm error on the legs shifts K by about 0.03.
CadQuoter unfolds every bent part with the shop's own K-factor: 0.33 to start with (DIN 6935 at R = T), set on the Press Brake & Bending page of the shop's settings. Measure one test bend with the calculator above and put the result there; every quote, flat pattern and cut length then follows it.
Worked example
A 100 mm strip of 2 mm steel is bent 90° on a V12, which gives an inside radius of about 2 mm (12 ÷ 6). Both legs measure 51.8 mm on the outside.
- Outside setback: tan 45° × (2 + 2) = 4.00 mm
- Bend allowance: 100 − 51.8 − 51.8 + 2 × 4.00 = 4.40 mm
- K: (4.40 ÷ 1.5708 − 2) ÷ 2 = 0.40
That is somewhat above DIN 6935's 0.325 for R = T: this machine and material stretch the outside a little less. Use 0.40 for this sheet and die from now on.
Do this for every part automatically
CadQuoter reads your customers' STEP, DXF and DWG files and prices laser cutting, bending, welding and tube cutting with your machines, sheets and rates, in seconds. Customers order and pay online; you get the order with the flat patterns.
The demo needs no account. 200 PLN / €50 + VAT per month, no commission.
Frequently asked questions
What is a good default K-factor?
For air bending with an inside radius near the thickness, about 0.33 (DIN 6935 gives 0.325 at R = T). Measured on mild steel air-bent on its usual die, shops often find 0.38 to 0.44, because the die makes a radius larger than the thickness: a test bend tells you yours. Many CAD templates ship with 0.5 or 0.44; 0.5 is right only for large radii and makes flats of tight bends slightly too long.
Is the K-factor different for stainless steel and aluminium?
Not by DIN 6935, which depends only on R / T. In practice stainless is bent on wider dies, so it gets a larger radius and a slightly higher K; soft aluminium can be bent tighter. A test bend on your own machine settles it.
What is the difference between the K-factor and the Y-factor?
The Y-factor (used in some CAD systems) is K × π ÷ 2: the same neutral layer, scaled for the bend allowance of a 90° bend. K = 0.33 is Y ≈ 0.52.
Why do my flat blanks come out too long?
Usually the K-factor is too high (often 0.5 from a CAD template) or the radius in the calculation is the drawing's and not the one the die makes. Measure a test bend and put both in.
Last checked: 14 Nov 2026